The Fitting Report prints details regarding a live or simulated fitting including indicators, configuration, audiogram, memories, graphs, etc. Only the data applicable to the hearing aid prints on the report. If the feature is supported and enabled, either a "checkmark" or "On" prints but if it's disabled, either dashes (....) or "Off" print. If the feature is not supported or enabled (e.g., telephone indicator, mute indicator, etc.), "N/A" prints. If fitting binaurally, each hearing aid prints on its own page. However, if fitting 2.4 GHz CROS/BiCROS devices, only the receiver aid prints. The Report Header options selected via Reports Preferences determines the logo/text and patient information that prints at the top of the report.
Whenever a session is saved in Inspire, if Include FastData when saving sessions to Noah is checked via General Preferences, a .pdf containing the first page of the Fitting Report and if checked, the REM Target Match graph, for all ear sides is saved to Noah.
Click on the Read Device Settings or Load a Previous Session radio button and then click Start.

Tip: Click
Print via Fitting
Summary or click on the Inspire Toolbar to print and/or preview
the report.
|

| Note: This option is only available if fitting comments were entered via Fitting Summary. If checked, the fitting comments print on the last page of the report. |

| Note: This option is only available if REM Target Match was applied during the current session. |
| Fitting Report | Description |
| Report Header | Manufacturer's logo, company's logo, or customized text. Prints based on the Report Header selected via Reports Preferences. |
| Customized for | Patient's name. Only prints if Patient Name was selected via Reports Preferences. |
| DOB | Patient's date of birth. Only prints if Patient Date of Birth was selected via Reports Preferences. |
| Session | Date of the current or retrieved session. Only prints if Session Date / Date of Test was selected via Reports Preferences. |
|
Fitting Report - Right/Left Ear |
|
| S/N, FW, Model, Matrix, Acoustic Options, VC Range/Reserve Gain; Step Size, VC Self Learning, Auto Experience Manager/Experience Level, Feedback Canceller, Fitting Formula, T2 On Demand, Power-On Delay, Auto Fall Alert, Self Check Status, Reminder Time, OCL Fast, CROS, and/or MPO Boost | Indicates the right/left hearing aid's serial number, firmware version, product family, circuit, and style, and the current configuration of the device's features. Only the features supported print. |
|
Audiogram |
|
| Air Thresholds (dB HL), Bone Thresholds (dB HL), and UCL Thresholds (dB HL) | Office system or In-situ air conduction, bone conduction, and UCL scores. An asterisk represents no response. |
|
Hearing Aid Features |
|
| Memory 1-4 and Stream Boost: On/Off | Lists the hearing aid's memories. |
| CROS (only prints if fitting or simulating CROS/BiCROS hearing aids) | Indicates the mode setting in the specific memory. |
| Hz Lowering* (Strength and Gain) (only prints if the hearing aid supports this feature) | Indicates the Frequency Lowering Bandwidth and Gain setting in the specific memory. |
| Tinnitus (Stimulus) (only prints if fitting or simulating Evolv AI, Livio Edge AI, Livio AI, Livio, Picasso, Halo iQ, Muse iQ, SoundLens Synergy iQ, Halo 2, Muse, SoundLens Synergy, Z Series, and Xino Tinnitus hearing aids) | Denotes whether or not Tinnitus is enabled in the specific memory. |
| Audio Streaming* (Streaming and Mic Setting) (only prints if the hearing aid is wireless [except Evolv AI, Livio Edge AI, Livio AI, Livio, Halo iQ, Halo 2, and Halo] and a wireless streaming accessory was enabled via Accessories) | Denotes whether or not audio streaming is enabled in the specific memory and the hearing aid's microphone setting while streaming. |
| DAI (DAI Setting and Dynamic FM) (only prints if the hearing aid supports this feature) | Indicates the DAI setting in the specific memory and denotes whether or not Dynamic FM is enabled. |
| Spatial HearingSpatial Hearing (only prints if fitting Picasso or Muse iQ CIC or Picasso or SoundLens Synergy iQ IIC hearing aids and this feature is available) | Denotes whether or not Spatial Hearing is enabled in the specific memory. |
| Feedback Canceller* (Setting) | Indicates the adjustment control setting in the specific memory. |
|
Adaptive Features |
|
| Memory 1-4, Stream Boost: On/Off and Ear to Ear | Lists the hearing aid's memories and Ear to Ear (only prints if the hearing aid is wireless). |
| Speech in Loud Noise, Speech in Noise/Speech and Noise/Noise, Quiet, Transients, Wind, and Machine/Machine Noise | Indicates the amount of adaptation per environment in the specific memory and denotes whether or not Ear to Ear is enabled in the specific environment. Only the environments supported print. |
| Auto Music (only prints if fitting or simulating select Evolv AI, Livio Edge AI, Livio AI, Livio, Picasso, Halo iQ, Muse iQ, SoundLens Synergy iQ, Halo 2, Muse, or SoundLens Synergy hearing aids) | Indicates the strength of music adaptation in the specific memory and denotes whether or not Ear to Ear is enabled. |
| Directionality (Mode, Immersion Directionality, Plus, and Roll Off) (only prints if the hearing aid supports a directional system) | Indicates the directional setting and if Immersion Directionality is enabled in the specific memory, denotes whether or not directionality plus is enabled, indicates how much low frequency amplification should be reduced when switching from omni to directional mode, and denotes whether or not Ear to Ear is enabled in the specific feature. Only the features supported print. |
|
Indicators |
|
| Low Battery, Power-On Sound, Power-Off Sound, Memory/Home, CROS Stream Start, CROS Stream Stop, TruLink/Stream Boost, Telephone, Hearing Aid Volume, Balance, Volume/Balance Control, Volume Max, Volume Increase, Volume Programmed/Volume Home, Volume Decrease, Volume Min, Tinnitus Level, Accessory Stream, Shutdown, Mute/Standby, Self Check: Pass, Self Check: Fail, Reminder, Comfort Boost, T2 Wake, Auto Fall Alert, Manual Alert, Assistant, Edge Mode, Favorite Button, and/or Cell Phone | Denotes whether or not the hearing aid's specific indicator is enabled. |
|
User Controls |
|
| Memory, Hearing Aid Volume, Balance, Tinnitus Level, Power Off, Mute, Stream, Accessory Volume, Thrive Assistant, Edge Mode, and/or T2 Remote | Indicates how the user controls are configured, denotes whether or not T2 Remote is enabled, and denotes whether or not Ear to Ear synchronization is enabled for the specific feature. Only the user controls and features supported print. |
|
Accessories |
|
| Remote, Remote Mic +, TV, Mini Remote Mic, Table Mic, Remote Control, SurfLink Mobile, SurfLink Media, Remote Mic, and Mini Mobile | Lists the Starkey accessories paired to the aids, or denotes whether or not the TruLink/SurfLink wireless accessory is enabled. |
|
Channel Specific Values (only prints if Include numeric info was selected when generating the report) |
|
| Display Values (2cc Coupler Gain - Speech), Memory 1-4 and Stream Boost: On/Off, Loud (dB), CR (Moderate), Moderate (dB), CR (Soft), Soft (dB), and MPO (dB SPL) (for Evolv AI, Livio Edge AI, Livio AI, Livio, Picasso, Halo iQ, Muse iQ, SoundLens Synergy iQ, Halo 2, Muse, Halo, Z Series, 3 Series, SoundLens, Xino Wireless, and Xino Tinnitus products) | Adjustment values per frequency. |
| Display Values (2cc Coupler Gain - Speech), Memory 1-4, Loud (dB), Overall (dB), Soft (dB), CR, MPO (dB SPL), and Kneepoint (dB SPL) (for Xino Wired, Wi Series, Ignite, X Series, S Series iQ, S Series, and E Series products) | Adjustment values per frequency. Overall (dB) refers to Moderate (dB). |
| Display Values (2cc Coupler Gain - Speech), Memory 1-4, Loud (dB), Soft (dB), CR, MPO (dB SPL), and Kneepoint (dB SPL) (for Xino Classic, Zōn, and Destiny products) | Adjustment values per channel. |
|
Fitting Graph* (only prints if Include graphs was selected when generating the report) |
|
| Fitting Graph | The graphical view currently selected prints on the fitting graph with the exception of Multicurve. If Auto Experience Manager was enabled and Show Auto Experience Manager final settings when the feature is enabled is selected via Target Preferences, the Auto Experience Manager's final gain settings print rather than the fitting formula's targets. |
| Graph Legend | Identifies the curves and shaded regions on the graph. The target and response levels print based on the Target Levels selected via Target Preferences. |
|
REM Target Match Graph* (only prints if Include REM Target Match was selected when generating the report) |
|
| Fitting Graph | Real-Ear Aided Response (REAR) measured curves matched to the targets for the inputs selected via REM Target Match when applied during the current session. |
| Graph Legend | Identifies the curves on the graph. |
|
Fitting Comments (only prints if Include Fitting Comments was selected when generating the report) |
|
| Fitting Comments | Fitting comments entered via Fitting Summary. |