Indicators for
Honor,
Pride, Halo, Z Series,
3 Series, Pride IIC, Xino,
Wi Series, Ignite,
X Series, and S Series
iQ
Products
Indicators set and adjust the signals that inform the patient of a low
battery, memory change, volume increase/decrease, etc., select the language
for speech indicators, and enable/disable any desired indicators. Adjustments
can be made globally or individually and can be demonstrated to the patient
through his/her hearing aids or to his/her family through the computer's
speakers.
The indicators available are based on the hearing aid connected or simulated
and its physical user control (e.g., rocker switch, push
button, etc.). For
example, Self
Check is only available if the hearing aid supports this feature, and
Favorite Button
and Cell Phone are only available for wireless hearing aids except
Honor
and Halo.
Indicators are enabled by default if the hearing aid features
are enabled. For example, Telephone is only enabled if a Telephone memory
is enabled.
Either a speech, chime (Power-On Sound only), or tone (pure or warble)
signal can be selected for most indicators. Speech automatically
defaults for all indicators that support speech, chimes automatically
default for Power-On Sound, and tone automatically defaults for all other
indicators.
The default presentation levels are based on the patient's audiogram.
If a valid audiogram exists, the default speech/chime and pure tone levels
are based on the patient’s Pure Tone Average and the default warble tone
levels are based on the patient’s threshold for the specific frequency. If a
valid audiogram has not been entered for the patient, all default levels
are 90 dB SPL. All levels can be increased or decreased in 5 dB increments.
Connect and select the desired hearing aid(s)
to adjust via .
Click on the Read Device Settings or radio
button and then click
.
Click Indicators.
Click All Indicators
to make any global adjustments if desired.
| Note: If
fitting binaurally but viewing monaurally, any tone and/or
speech/chime adjustments apply to the selected ear side only.
However, any voice language and/or enable automatic indicator
level change selections are automatically assigned to both
ears because the settings must match between devices. |
| |
| Field Name |
Description |
Details |
| Tone |
Increases, decreases,
or resets all enabled tonal indicator levels. |
Click to increase or to decrease all tonal
levels 5 dB. Subsequent clicks increases or decreases all
levels in 5 dB increments. Once the maximum or minimum level
is reached, the button is disabled. Click Reset
to revert all tonal indicators back to their Best Fit level
(=). |
| Speech/Chimes |
Increases, decreases,
or resets all enabled speech/chime indicator levels. |
Click to increase or to decrease all speech/chime
levels 5 dB. Subsequent clicks increases or decreases all
levels in 5 dB increments. Once the maximum or minimum level
is reached, the button is disabled. Click Reset
to revert all speech/chime indicators back to their Best Fit
level (=). |
| Voice
Language |
Selects the
language for all speech indicators. |
If
Auto Path was run previously, the voice language selected
automatically defaults. If simulating, the
Voice Language selected
via automatically defaults. |
| Enable
automatic indicator level change |
Denotes whether or not the
hearing aid should automatically adjust the volume level based
on the noise level in a specific environment. |
This feature is automatically
checked by default. |
To adjust a specific indicator, click the checkbox
to the right of the indicator to enable or disable.
| Note: If the
hearing aid feature hasn't been enabled, this field is disabled.
Enable the desired feature first (e.g., memory, volume, tinnitus,
etc.) via the appropriate
screen. For Volume Max and Volume Increase, reserve gain must
be available via
and for Self Check, the hearing aid must have a baseline and
User-Initiated Self Check
must be selected via . When an indicator is enabled, the
average level of all enabled indicators of that type (tone
or speech/chime) defaults. |
| |
| Note: For
Honor, Pride, and Pride IIC
products, only one Volume and one Tinnitus (must contain either
a rocker switch or push button, or support T² remote control)
indicator will be available but will include indicators for
Volume Max, Volume Home, Volume Steps (select products only),
and Volume Min, and Tinnitus Max, Tinnitus Home, Tinnitus
Steps, and Tinnitus Min, respectively. If the Volume or Tinnitus
indicator is enabled, tones for all volume or tinnitus changes
will be presented at the level and stimulus selected for the
Volume or Tinnitus indicator. |
| |
| Note: For
CROS/BiCROS products, indicators can only be enabled or disabled
for the receiver aid, however, if Low Battery is enabled,
the Speech Alert Tone will be presented in the transmitter
after the speech or warble tone indicating that this device's
battery is low. The receiver aid will only play the speech
or warble tone when this device's battery is low, therefore,
only this indicator can be demonstrated to the patient. CROS
Stream Start and CROS Stream Stop can only be enabled or disabled
if at least one memory is configured for CROS or BiCROS mode
via . Volume
and Balance Control are combined and can only be enabled or
disabled if the patient can adjust either the volume or balance
via the hearing aid's physical user control and/or wireless
accessory. |
| |
| Note: TruLink/Stream
Boost is only available for Honor
and Halo
products. For Halo
products specifically, this indicator is linked
to the Memory Change indicator, therefore, it cannot be enabled
or disabled independently. If Memory Change is enabled, tones
will only be presented if the TruLink
or Stream Boost memory is initiated manually
via the push button (BTE only) or the iOS device. |
| |
| Note: If the
Favorite button is configured for None,
Jump to Memory 4,
Tinnitus On/Off,
or Initiate Self Check
via , the Favorite Button indicator
cannot be enabled. |
| |
| Note: T2
Wake cannot be enabled or disabled via this screen. Rather,
T2 Remote Control,
if applicable, and/or T2 on Demand must be
enabled or disabled via User Controls
or Fitting Summary. |
| |
| Note:
If enabling or disabling Self Check: Pass or Self
Check: Fail, both indicators will be enabled or disabled because
the state of these two indicators must match. |
| |
Note: If
viewing binaurally, both hearing aids will be enabled or disabled
based on the selection. To enable or disable the right or
left hearing aid only, click or and then click the desired
checkbox. |
Click on the specific indicator to adjust if
desired.
| Note: Only
enabled indicators can be adjusted. |
Click
to
increase or
to decrease
the tone or speech/chime level 5 dB. Subsequent clicks increase or
decrease the level in 5 dB increments.
| Note: If
global adjustments were made in step 5, any adjustments made
to a specific indicator are based on the new global level.
For example, if the global tone level was increased +5 dB
and then the tone level for a specific indicator is increased
+5 dB, the new level for that indicator is +10 dB. If global
adjustments are made after a specific indicator is adjusted,
the level for that indicator will be adjusted again. |
| |
| Tip: Once
the maximum or minimum level is reached, the button is disabled.
Click Reset to revert the indicator
back to its Best Fit level (=). |
Select the desired Stimulus
from the drop down list.
| Note: Based
on the indicator selected determines the available stimulus
(speech/chime, warble, or specific pure tones). If the
stimulus is changed from speech/chime to tone or vice versa,
the average level of all enabled indicators of that type (tone
or speech/chime) defaults. |
| |
| Note: If
fitting binaurally but viewing monaurally, the stimulus selected
is automatically assigned to the opposite ear side because
the setting must match between devices. |
If Speech
was selected in step 9, check or uncheck Speech
Alert Tone to enable or disable the alert tone.
| Note: If
checked, an alert tone will play prior to the speech indicator.
The alert tone level will mimic the speech indicator level
selected. |
| |
| Note: If
fitting binaurally but viewing monaurally, the setting selected
is automatically assigned to the opposite ear side because
the state of this feature must match between devices. |
Click the Indicator Name
button in the Play section
to demonstrate the indicator to the patient through his/her hearing
aid(s).
| Note: This
button is only enabled during a live fitting. If viewing binaurally
and the indicator is enabled in both hearing aids, the indicator
is presented in the left aid first, followed by a 2 second
delay before it's presented in the right aid. |
Click the Indicator Name
button in the Demo section
to demonstrate the indicator to the patient's family through the computer's
speakers if desired.
| Note: If
Speech Alert Tone
was selected in step 10, the tone is not played during the
speaker demonstration. |